Prices

Download price
 Name  Description                    Retail price, EUR (without VAT)

 SPECTRON FIRE DETECTORS

1. Fire detectors: general purpose industrial version

1.1. Multiband fire detectors of Spectron-600 series

Multiband fire detectors of Spectron 600 series

Spectron-600 fire detectors are used  at outdoor premises and indoors with heavy optical interference . Viewing angle 100°. Actuation time is selected by the Customer. Two-wire and four-wire connection.  Upower supply - 9...28V. IP66. Self monitoring function, fault signaling.

Spectron-601-C

Super resistant to heavy optical interference. Determines manual arc and argon welding as false interference!  Operation area - 550 sq.m. Fire detection range as per 1 class - 25m. Istandby 0,3 mA, Ifire 3-15 mA. Actuation time 3, 10, 15, 22 sec. Temperature range -40...+70°С. Body - ABS-plastic, 69х103х45 mm.

218,00  

Spectron-601-C-E

Super resistant to heavy optical interference. Determines manual arc and argon welding as false interference!  Operation area - 550 sq.m. Extended set of configurable parameters and customized setting of the detector for operation conditions of the facility. Fire detection range as per 1 class - 25m. Istandby 0.3 mA, Ifire 3-15 mA. Actuation time 3, 10, 15, 22 sec. Temperature range -40...+70°С. Body - ABS-plastic, 69х103х45 mm.

222,00  

Spectron-601

Resistant to heavy optical interference. Operation area - 750 sq.m. Fire detection range as per TP5- 30m, Istandby 0.55 mA, Ifire 3-15 mA. Actuation time 3, 7, 15, 22 sec. Temperature range -40...+55°С. Body - ABS-plastic, 69х103х45 mm.

123,00  

Spectron-601-M

Resistant to heavy optical interference. Operation area - 750 sq.m. Fire detection range as per TP5-30 m, Istandby 0.55 mA, Ifire 3-15 mA. Actuation time 3, 7, 15, 22 sec. Temperature range -40...+55°С. Body - aluminum alloy, 250х150 diameter 70 mm.

144,00  

Spectron-601-M-E

Resistant to heavy optical interference. Operation area - 750 sq.m. Extended set of configurable parameters and customized setting of the detector for operation conditions of the facility. Fire detection range as per TP5-30 m, Istandby 0.55 mA, Ifire 3-15 mA. Actuation time 3, 7, 15, 22 sec. Temperature range -40...+55°С. Body - aluminum alloy, 250х150 diameter 70 mm.

152,00  

1.2. Infrared fire detectors of Spectron-200 series

Infrared fire detectors of Spectron-200 series

Fire detectors Spectron-200 for premises with minor window-glazing.  Maximum operating area 930 sq.m. Detection range 30m as per TP5. Viewing angle 120°. Response time (7, 15, 22 sec.). Upower supply - 9...28V. Istandby 0.35 mA. Ifire 3-15 mA.  t - 50..+55°С. Body - ABS-plastic, 69х103х45 mm.

Spectron-201

For two-wire alarm circuits.   IP41. 

37,00  

Spectron-205

For two-wire and four-wire alarm circuits.  IP41.Self monitoring function, fault signaling.

50,00  

Spectron-204

For two-wire and four-wire alarm circuits.  IP68. Self monitoring function, fault signaling.

58,00  

Infrared fire detectors of Spectron-200 series with remote optical element.

Fire detectors Spectron-200 with remote optical element (OE), intended for premises with minor window-glazing. Response time 30 sec., max. Detection range 30m as per TP5. Electronic unit: Upower supply - 9...28V. Temp.range from - 50 to +55°С. Remote optical element:  Temp. range from - 50 to +70°С.  Length of removable electric cable for OE ranges from 1 to 45 m. (1m-fold) is fixed at order.

Spectron-210

For two-wire alarm circuits.  Maximum operating area - 700 sq.m. Viewing angle 90°.  Istandby 0.2 mA, Ifire 3-22 mA is set by the Customer.   IP68 - electr. unit. IP68 - OE. Electronic unit body - aluminum alloy, 125x130x35mm.

99,00  

Spectron-210-R

For four-wire alarm circuits. Maximum operating area - 700 sq.m. Viewing angle 90°.  Istandby 0.2 mA, Ifire 3-22 mA is set by the Customer. IP68 - electr. unit. IP68 - OE. Electronic unit body - aluminum alloy, 125x130x35mm.

103,00  

Cable Spectron-OE-M

Electric cable in metal hose for fire detectors Spectron-210 and Spectron-210R, 1m

5,00  

Optical filters

OF10 and OF20. The filters are recommended for monitored desensitization of IR-detectors Spectron-200 series at premises with high background illumination.

1,00  

1.3. Ultraviolet fire detectors of Spectron-400 series

Ultraviolet fire detectors of Spectron-400 series

Fire detectors Spectron-400 for indoor premises with large widow-glazing. Fire detection range 50 m as per TP5. Response time (3, 7, 15, 22)sec. Upower supply - 9...28V. Istandby 0.35 mA, Ifire 3-15 mA. t from - 40 to +70°С

Spectron-401

 For two-wire and four-wire alarm circuits. Operation area - 2,000 sq.m. Viewing angle 100°. IP66, Self monitoring function, fault signaling. Body - ABS-plastic, 69х103х45 mm.

82,00  

Spectron-401-M

 For two-wire and four-wire alarm circuits. Operation area - 2,000 sq.m. Viewing angle 100°. IP66, Self monitoring function, fault signaling. Body - aluminum alloy, 250х150 diameter 70 mm.

115,00  

Spectron-403

For two-wire alarm circuits.  Operation area 2,400 sq.m. Viewing angle 120°.IP41, Body - ABS-plastic, 69х103х45 mm.

60,00  

2. Explosion-proof fire detectors

2.1. Explosion-proof fire detectors of Spectron-600-Exd series (explosion-proof enclosure)

Fire
detectors
of Spectron-600 series
for class 1 and 2 explosion-hazard areas

Explosion-proof fire detectors Spectron-600-Exd, Intended for use at outdoor premises and indoors. Super resistant to heavy optical interference. Determines manual arc and argon welding as false interference. Explosion-proof marking РВ ЕхdI / 1ЕхdIICT5 (mine config.).  Maximum operation area 500 sq.m. Detection range per class 1 - 25 m. as per TP5 and TP6. Viewing angle 90°. Preheat. t from - 70 to + 75°С. IP68. Four-wire connection, sensitivity adjustment “Far” and “Close”. Self monitoring function, fault signaling. Overall dimensions 300х200х120. In the course of order please specify type of cable gland (not included in the scope of supply).

Spectron-601-Exd

Body - stainless steel. Explosion-proof marking РВ ЕхdI / 1ЕхdIICT6 (mine vers.). In-built   event recorder.  Determines gas flare, manual arc and argon welding as false interference. Indication of preliminary fire detection for IR and UV channel. HART and Modbus/RTU protocol digital interface. Glass dust control.

 2 198,00  

Spectron-VM-Exd-N

Explosion-proof video module for fire detector Spectron-601-Exd. Body - stainless steel. Explosion-proof marking РВ ЕхdI / 1ЕхdIICT6 (mine vers.). AHD, 1920x1080 resolution

410,00  

Spectron-601-Exd-V

Response time 3, 10, 15, 22 sec. Upower supply -9..28V. Istandby - 6 mA, Ifire - 30 mA.  I with preheat up to 250mA. Body - aluminum.

636,00  

Spectron-601-Exd-M

Response time 3, 10, 15, 22 sec. Upower supply -9..28V. Istandby - 6 mA, Ifire - 30 mA.  I with preheat up to 250mA. Body - galvanized steel .

755,00  

Spectron-601-Exd-S-M

Response time 3, 10, 15, 22 sec. Upower supply -9..28V. Istandby - 6 mA, Ifire - 30 mA.  I with preheat up to 250mA. Body - galvanized steel. Indication of preliminary fire detection.

759,00  

Spectron-601-Exd-M-HART/Modbus

Digital interface for  HART or Modbus/RTU protocols. Capability of address assignment. Response time 10 sec. Upower supply - 9...28V. Istandby - 50 mA, Ifire - 70 mA.  I with preheat up to 250mA. Body - galvanized steel.

866,00  

Spectron-601-Exd-S-M-HART/Modbus

Digital interface for  HART or Modbus/RTU protocols. Capability of address assignment. Response time 10 sec. Upower supply - 9...28V. Istandby - 50 mA, Ifire - 70 mA.  I with preheat up to 250mA. Body - galvanized steel. Indication of preliminary fire detection.

874,00  

Spectron-601-Exd-N

Response time 3, 10, 15, 22 sec. is selected by the Customer. Upower supply - 9...28V. Istandby - 6 mA, Ifire - 30 mA.  I with preheat up to 250mA.  Body - stainless steel.

902,00  

Spectron-601-Exd-S-N

Response time 3, 10, 15, 22 sec. is selected by the Customer. Upower supply - 9...28V. Istandby - 6 mA, Ifire - 30 mA.  I with preheat up to 250mA. Body - stainless steel. Indication of preliminary fire detection.

907,00  

Spectron-601-Exd-N-HART/Modbus      

Digital interface for HART or Modbus/RTU protocols. Capability of address assignment. Response time 10 sec. Upower supply - 9...28V. Istandby - 50 mA, Ifire - 70 mA.  I with preheat up to 250mA. Body - stainless steel.

1 017,00  

Spectron-601-Exd-S-N-HART/Modbus      

Digital interface for HART or Modbus/RTU protocols. Capability of address assignment. Response time 10 sec. Upower supply - 9...28V. Istandby - 50 mA, Ifire - 70 mA.  I with preheat up to 250mA. Body - stainless steel. Indication of preliminary fire detection.

1 021,00  

Test explosion-proof detector Spectron-IT-12-Exd               (black)

Test explosion-proof detector for remote functionality test of detectors Spectron-600-Exd series. Operation range - 25m; Battery life - 50 hrs;

460,00  

Test explosion-proof detector Spectron-IT-12-Exd (red)

Test explosion-proof detector    for remote adjustment of basic parameters of Spectron-600-Exd series detectors;  Operation range - 25 m; battery life - 50 hrs.;

 689,00  

Optic sunshade
Spectron-01-M

Optic sunshade is intended for reduction of viewing angle of Spectron-601-Exd fire detectors (all configurations).

58,00  

Sunscreen SZK-02

Sunscreen for fire detectors Spectron-601-Exd and Spectron-401-Exd

18,00  

2.2. Explosion-proof ultraviolet fire detectors of Spectron-400-Exd series (explosion-proof enclosure)

Fire
detectors
of Spectron-400 series
for class 1 and 2 explosion-hazard areas

Explosion-proof fire detectors Spectron-400-Exd are designed for indoor premises with large window-glazing area and resistant to optic interference, including solar emission and flashing lights. Explosion-proof marking РВ ЕхdI / 1ЕхdIICT5 (mine config.). Maximum operation area 2,000 sq.m. Fire detection range 50 m as per TP5.  Viewing angle 100°. Preheat. t from -70 to +90°С. IP68. Two-wire and four-wire connection, self monitoring function, fault signaling. Upower supply - 9...28V. I standby - 0,6 mA. I with preheat up to 250mA. Overall dimensions 300х200х120. In the course of order please specify type of cable gland (not included in the scope of supply). 

Spectron-401-Exd-A

Response time 3, 7, 15, 22 sec. Aluminum body. 1ЕхdIICT5 type of explosion protection.

319,80  

Spectron-401-Exd-M

Response time 3, 7, 15, 22 sec. Body - galvanized steel with powder coating.

344,40  

Spectron-401.01-Exd-M

High-speed “flash”- responsive flame detector.  Response time  0.1; 0.5; 1; 2 sec. Body - galvanized steel.

393,60  

Spectron-401-Exd-N

Response time 3, 7, 15, 22 sec. Body - stainless steel.

451,00  

Spectron-401.01-Exd-N 

High-speed “flash”-responsive flame detector.  Response time  0.1; 0.5; 1; 2 sec. Body - stainless steel.

516,60  

SZK-02

Sunscreen for fire detectors Spectron-601-Exd and Spectron-401-Exd.

18,04  

2.3. Explosion-proof infrared fire detectors of Spectron-200 series.

Fire detector Spectron-202 for class 1 and 2 explosion-hazard areas

Explosion-proof flame detector Spectron-202 for indoor premises with minor window-glazing area. 1ExmIIT6X  explosion-proof marking. Maximum operation area 930 sq.m. Fire detection range - 30m as per TP5. Response time 7, 15, 22 sec., viewing angle 120°,  self monitoring function, fault signaling. Two-wire and four-wire connection. U-power supoply.9...28V. I in standby mode 0.35 mA, I . t-oper.-50...+55°С. IP68, Body - ABS-plastic, 69х103х45 mm.

70,00  

Fire detectors of Spectron-200 series with remote optical element intended for class 0, 1, 2 explosion-hazard areas

Explosion-proof fire detectors Spectron-220 with remote optical element (OE) intended for indoor premises with minor window-glazing. Maximum operation area 700 sq.m. Fire detection range 30 m as per TP5. Response time up to 30 sec. Viewing angle 90°. Electronic unit: U-alarm circuit.9...28V. I standby - 0,2 mA, I fie 3-22 mA. t from - 50 to +55°С. IP66. Overall dimensions 125х130х35mm. Optical element: explosion-proof marking 0ExsIIT4,  IP68. Temp. range from - 60 to +120°С. Length of removable fiber-optic cable of OE ranges from 1 to 45 m. (1m-fold) and is fixed at order.

Spectron-220

For two-wire alarm circuits.  Electronic unit w/o explosion protection.

103,00  

Spectron-220-R

For four-wire alarm circuits. Electronic unit w/o explosion protection.

107,00  

Spectron-220-Ex

For two-wire alarm circuits.  Explosion-proof marking of electronic unit 1ExmIIT6Х

164,00  

Spectron-220-R-Ex

For four-wire alarm circuits. Explosion-proof marking of electronic unit 1ExmIIT6Х

169,00  

Fiber-optic cable

Fiber-optic cable in metal hose for fire detectors Spectron-220 and Spectron-220-Ex, 1 m

13,00  

Clamp coupling

The coupling is used to seal S/E cable duct through a wall between areas of different explosion-hazard degrees. Standard length of coupling - 160 mm.  
Extension of coupling length - by special order at extra cost.

18,00  

Optical filters

OF10 and OF20. The filters are recommended for monitored desensitization of IR-detectors Spectron-200 series at premises with high background illumination.

1,00  

2.4. Explosion-proof fire detectors of Spectron-600-Exi (intrinsically-safe circuit)

Fire detectors of Spectron-600 series intended for class 0,1 and 2 explosion-hazard areas

Explosion-proof fire detectors Spectron-600-Exi. The detectors are used for outdoor areas and indoor premises with heavy optical interference. OExiallCT4 X explosion-proof marking.   Two-wire and four-wire connection.  Self monitoring function, fault signaling. Upower supply - 9...28V. Viewing angle 100°. IP68.

Spectron-601-Exi-S

Super resistant to heavy optical interference. Determines manual arc and argon welding as false interference!  Maximum operation area 550 sq.m. Operation range per 1 class - 25m as per TP5 and TP6. Response time 3, 10, 15, 22 sec. I standby - 0.3 mA, I fire 3-15mA. Body - ABS-plastic. Temperature range from - 40 to + 70°С. Overall dimensions 69x103х120 mm.

287,00  

Spectron-601-Exi-S-E

Super resistant to heavy optical interference. Determines manual arc and argon welding as false interference!  Maximum operation area 550 sq.m. Extended set of configurable parameters and customized setting of the detector for operation conditions of the facility. Operation range per 1 class - 25m as per TP5 and TP6. Response time 3, 10, 15, 22 sec. I standby - 0.3 mA, I fire 3-15mA. Body - ABS-plastic. Temperature range from - 40 to + 70°С. Overall dimensions 69x103х120 mm.

 296,00  

Spectron-601-Exi

Body - ABS-plastic. Maximum operation area - 700 sq.m. Operation range as per TP5 up to 30m. Response time 3, 7, 15, 22 sec.  I standby - 0.55 mA, I fire 3-15mA.  Temperature range from - 40 to + 55°С. Overall dimensions 69х103х120 mm.

181,00  

Spectron-601-Exi-M

Body - aluminum alloy. Maximum operation area - 700 sq.m. Operation range as per TP5 up to 30m. Response time 3, 7, 15, 22 sec.  I standby - 0.55 mA, I fire 3-15mA.  Temperature range from - 40 to + 55°С. Overall dimensions 250х150 diameter 70mm.

246,00  

Intrinsically safe barrier Spectron-IB-01

Intrinsically safe active-type barrier Spectron-IB-01   for power-supply circuits of fire detectors, current consumption 0.25 mA, max. Output voltage 12V. Peal current 500 mA. R inner - 5.1 Ohm

46,00  

Intrinsically safe barrier Spectron-IB-02

Intrinsically safe active-type barrier  Spectron-IB-02 designed for loops of Fire alarm control and indicating equipment. Powered from alarm circuit. Current consumption 0.25 mA. Output voltage 24 V. Peak current 100 mA. R inner - 6.8 Ohm

46,00  

2.5. Explosion-proof ultraviolet fire detectors of Spectron-400-Exi series (intrinsically-safe circuit) 

Explosion-proof fire detectors of Spectron-400 series
intended for class 0, 1 and 2 explosion-hazard areas.

Explosion-proof fire detectors Spectron-400-Exi. OExiaIICT4Х explosion-proof marking. Maximum operation area - 2000 sq.m. Operation range as per TP5 up to 50 m. Self monitoring function, fault signaling. Two-wire and four-wire connection, Upower suppl. - 9...28V.   I standby - 0.35 mA, I fire 3-15mA. Viewing angle 100°. Temperature range from - 40 to +70°С. IP68. Actuation time and “Fire” mode current are selected by the Customer.

Spectron-401-Exi

Response time 3, 7, 15, 22 sec. Body - ABS-plastic. Overall dimensions 69х103х120 mm.

148,00  

Spectron-401-Exi-M

Response time 3, 7, 15, 22 sec. Body - aluminum alloy. Overall dim. 250х150 diameter 70mm.

205,00  

Spectron-401.01-Exi

High speed “flash”-responsive flame detector Response time 0.1; 0.5; 1; 2 sec.  Body - ABS-plastic.  Overall dimensions 69х103х120 mm.

177,00  

Spectron-401.01-Exi-M

High speed “flash”-responsive flame detector Response time 0.1; 0.5; 1; 2 sec. Body - aluminum alloy. Overall dim. 250х150 diameter 70mm.

230,00  

Intrinsically safe barrier Spectron-IB-01

Intrinsically safe active-type barrier for power-supply circuits of fire detectors, current consumption 0.25 mA, max. Output voltage 12V. Peal current 500 mA. Rinner - 5.1 Ohm

46,00  

Intrinsically safe barrier Spectron-IB-02

Intrinsically safe active-type barrier for loops of Fire alarm control and indicating equipment. Powered from alarm circuit. Current consumption 0.25 mA. Output voltage 24 V. Peak current 100 mA. Rinner - 6.8 Ohm

46,00  

3. Explosion-proof manual detectors

3.1. Explosion-proof manual detector of Spectron-535-Exd series

Manual detectors of Spectron-535 series for class 1 and 2 explosion-hazard areas

Explosion-proof manual detector Spectron-535-Exd is designed for “FIRE” signaling at actuator manual switch-on.  1ExdIIСT6 (1 and 2 areas) explosion-proof marking. Two-wire and four-wire connection. Upower supply - 9...28V. Istandby 0,05 mA. Ifire - 25 mA.  t from -70°C to +85°C. IP67. Overall dimensions 130х90х116. In the course of order please specify type of cable gland (not included in the scope of supply).

Spectron-535-Exd-M

Body - aluminum alloy  1ExdIIST6 explosion-proof marking.

58,00  

Spectron-535-Exd-N

Body - stainless steel 12Х18Н10T. РВ ЕхdI/1ExdIICТ6 explosion-proof marking allows for use of Spectron-535-Exd-N in shafts and mines.

140,00  

3.2. Explosion-proof manual detector Spectron-512-Exd

Manual detectors of Spectron-512 series for class 1 and 2 explosion-hazard areas

Explosion-proof manual detector Spectron-512-Exd-M.  The detector is used for “FIRE” signaling at actuator manual switch-on. Self monitoring function, fault signaling, two-wire connection. IP68. t from -70°C to +85°C. Upower supply - 9...28V. Istandby 0.25 mA. Ifire - 3-15 mA. Overall dimensions 123х106х122. In the course of order please specify type of cable gland (not included in the scope of supply).

Spectron-512-Exd-M-IPR-A

Version as per class "А". Body material - aluminum alloy. 1ExdIIСT6 Explosion-proof marking.

128,00  

Spectron-512-Exd-M-IPR-B

Version as per class "В". Body material - aluminum alloy. 1ExdIIСT6 Explosion-proof marking.

128,00  

Spectron-512-Exd-N-IPR-A

Version as per class "А". Body material - stainless steel 12Х18Н10Т. Mine explosion-proof marking РВ ЕхdI/1ExdIICТ6.

214,00  

Spectron-512-Exd-N-IPR-B

Version as per class "В". Body material - stainless steel   12Х18Н10Т.  Mine explosion-proof marking РВ ЕхdI/1ExdIICТ6.

214,00  

4. Explosion-proof remote starters

4.1. Explosion-proof remote starters Spectron-535-Exd

Remote starters of Spectron-535 series for class 1 and 2 explosion-hazard areas

Explosion-proof starter Spectron-535-Exd-UDP is intended for manual switch of “FIRE FIGHTING”, “SMOKE REMOVAL“, “EVACUATION” systems.  Upower supply - 9...28V. Istandby 0,05 mA. Ifire - 25 mA. IP67. t from -70°C to +85°C. Overall dimensions 130х90х116. In the course of order please specify type of cable gland (not included in the scope of supply).

Spectron-535-Exd-M-UDP-01

"FIRE-FIGHTING ACTIVATION" (yellow) Body - aluminum alloy. 1ExdIIСT6 explosion-proof marking.

66,00  

Spectron-535-Exd-M-UDP-02

"SMOKE-REMOVAL ACTIVATION"(orange) Body - aluminum alloy. 1ExdIIСT6 explosion-proof marking.

66,00  

Spectron-535-Exd-M-UPD-03

"EMERGENCY EXIT" (green) Body - aluminum alloy АК12. 1ExdIIСT6 explosion-proof marking.

66,00  

Spectron-535-Exd-N-UDP-01

"FIRE-FIGHTING ACTIVATION" (yellow) Body - stainless steel 12 KH18N10T. РВ ЕхdI/1ExdIICТ6 Explosion-proof marking.

140,00  

Spectron-535-Exd-N-UDP-02

"SMOKE-REMOVAL ACTIVATION"(orange) Body - stainless steel 12KH18N10Т. РВ ЕхdI/1ExdIICТ6 Explosion-proof marking.

140,00  

Spectron-535-Exd-N-UDP-03

"EMERGENCY EXIT" (green). Body - stainless steel 12Х18Н10Т. РВ ЕхdI/1ExdIICТ6 Explosion-proof marking.

140,00  

4.2. Explosion-proof remote starter Spectron-512-Exd

Remote starters of Spectron-512 series for class 1 and 2 explosion-hazard areas

Explosion-proof starter Spectron-512-Exd-UDP is intended for manual switch of "FIRE FIGHTING", "SMOKE REMOVAL", "EVACUATION" systems.Self monitoring function, fault signaling. Two-wire connection. IP68. t from -70°C to +85°C. Upower supply - 9...28V. I standby 0.25 mA. Ifire - 3-15 mA.   Overall dimensions 123х106х122. In the course of order please specify type of cable gland (not included in the scope of supply).

Spectron-512-Exd-M-UDP-01

"FIRE-FIGHTING ACTIVATION"(yellow). Body - aluminum alloy 1ExdIIСT6 explosion-proof marking.

123,00  

Spectron-512-Exd-M-UDP-02

"SMOKE-REMOVAL ACTIVATION"(orange). Body - aluminum alloy 1ExdIIСT6 explosion-proof marking.

123,00  

Spectron-512-Exd-M-UDP-03

"EMERGENCY EXIT"(green). Body - aluminum alloy  1ExdIIСT6 explosion-proof marking.

123,00  

Spectron-512-Exd-N-UDP-01

"FIRE-FIRE ACTIVATION" (yellow). Body - stainless steel 12Х18Н10Т. РВ ЕхdI/1ExdIICТ6 Explosion-proof marking.

214,00  

Spectron-512-Exd-N-UDP-02

"SMOKE-REMOVAL ACTIVATION" (orange). Body - stainless steel 12Х18Н10Т. РВ ЕхdI/1ExdIICТ6 Explosion-proof marking.

214,00  

Spectron-512-Exd-N-UDP-03

"EMERGENCY EXIT" (green). Body - stainless steel 12Х18Н10Т. РВ ЕхdI/1ExdIICТ6 Explosion-proof marking.

214,00  

5. Explosion-proof spot heat fire detectors Spectron-101

Explosion-proof spot heat fire detectors Spectron-101 for class 1 and 2 explosion-hazard areas

Heat spot fire detector Spectron-101-Exd is designed to detect ignition accompanied by emission of large amount of heat. Temperature classes are selected by the Customer. Intrinsically safe circuit is not required U power supply - 9...28V.  Istandby 0,25 mA, Ifire 3-15 mA. IP68. t  -75°C ... +85°C. Temperature range of sensitive elements -65°C ... +130°C. In the course of order please specify type of cable gland (not included in the scope of supply).

Spectron-101-R

Body - aluminum alloy. 1Exd[ia]IICT4 explosion-proof marking. Maximum.  Temperature classes A1, A2, А3, B, C, D, E. U-alarm circuit.9...28V. Two-wire connection.

54,00  

Spectron-101-T-R

Self monitoring function. Fault signaling. Body - aluminum alloy. 1Exd[ia]IICT4 / T5/T6X explosion-proof marking. The detector is setup (adjusted) as full power, differential, full power-differential in temperature classes A1, A2, A3, B, C, D, E, A1R, A2R, A3R, BR, CR, DR, ER. Two-wire and four-wire connection.                Periodic inspection does not require disassembly.

70,00  

Spectron-101-T-R-N

Self monitoring function. Fault signaling. Body - stainless steel. Explosion-proof markingРВ Exd[ia]I X / 1Exd[ia]IICT4/Т5/Т6 X mine configuration.  The detector is setup (adjusted) as full power, differential, full power-differential in temperature classes A1, A2, A3, B, C, D, E, A1R, A2R, A3R, BR, CR, DR, ER. Two-wire and four-wire connection.  Periodic inspection does not require disassembly.

140,00  

 

 Name

  Description  

Retail price, EUR (without vat). 

EXPLOSION-PROOF FIRE ALARM DEVICES PROMETHEUS

1.  Explosion-proof light displays TSV-Ex-Prometheus

Explosion-proof  light display
TSV-Exm-Prometheus, intended for class 1 and 2 explosion-hazard areas

Explosion-proof light display TSV-Exm-Prometheus. The device is intended for use as light alerter in security and fire alarm systems or as information display.  The device is used in class 1 and 2 explosion-hazard areas, underground workings, mines and their ground-based structures.  
Explosion-proof marking 1ExmbIICT6 Gb X/РВ ExmbIMb X (compound sealing).  IP68. Operating temperature ranges from -70 to 85 °С. Two-wire or four-wire connection is available.
In the course of order please specify text and background color.

 

TSV-Exm-М-Prometheus 12-36 V

Body - galvanized steel. Power voltage 12-36 VDC.

103,00

TSV-Exm-М-Prometheus 220 V

Body - galvanized steel. Power voltage 220 VAC.

103,00

TSV-Exm-N-Prometheus 12-36 V

Body - stainless steel  12Х18Н10Т. Power voltage 12-36 VAC/DC.

226,00

TSV-Exm-N-Prometheus 220 V

Body - stainless steel  12Х18Н10Т. Power voltage 220 VAC.

226,00

Explosion-proof light display
TSV-Exi-Prometheus, intended for class 0, 1 and 2 explosion-hazard areas

Explosion-proof light display TSV-Exi-Prometheus. The device is intended for use as light alerter in security and fire alarm systems or as information display.  The device is used in class 0, 1 and 2 explosion-hazard areas, underground workings, mines and their ground-based structures. Two-wire or four-wire connection is available.
Explosion-proof marking 0ExiaIICT6 X / РОExiaI X (intrinsically safe circuit). IP68. Operating temperature from -70 to +85 °С.
In the course of order please specify text and background color.

 

TSV-Exi-N-Prometheus -12-36 V

Body - stainless steel  12Х18Н10Т. Power voltage 12-36 VDC.

222,00

Explosion-proof light display TSB-Exd-Prometheus, intended for class 1 and 2 explosion-hazard areas

Explosion-proof light display TSV-Exd-Prometheus. The device is intended for operation as light alerter in security and fire alarm systems. The device is used at class 1 and 2 explosion-hazard areas. Operating temperature from - 70 to +85°C. IP67.
In the course of order please specify type of cable gland (not included in the scope of supply), text and background color.

 

 TSV-Exd-А-Prometheus 12-36 V

Body - aluminum alloy AK6. 1ExdIIBT6 X explosion-proof marking. Power voltage 12-36 VDC.

189,00

 TSV-Exd-А-Prometheus 220 V

Body - aluminum alloy AK6. 1ExdIIBT6 X explosion-proof marking .Power voltage 220 VAC.

205,00

 TSV-Exd-N-Prometheus 12-36 V

Body - stainless steel  12Х18Н10Т. РВ ExdI X/1ExdIIBT6 X explosion-proof marking. Power voltage 12-36 V AC/DC.

353,00

 TSV-Exd-N-Prometheus 220 V

Body - stainless steel  12Х18Н10Т. РВ ExdI X/1ExdIIBT6 X explosion-proof marking. Power voltage 220 VAC.

369,00

2. Sound-and-light explosion-proof displays TSZV-Ex-Prometheus

Sound-and-light explosion-proof display
TSZV-Exm-Prometheus, intended for class 1 and 2 explosion-hazard areas

Explosion-proof sound-and-light display TSZV-Exm-Prometheus. The device is used as sound-and-light alerter in security and fire alarm systems or as information display. The device is used in class 1 and 2 explosion-hazard areas, underground workings, mines and their ground-based structures.   Explosion-proof marking 1ExmbIICT6 Gb X/РВ ExmbIMb X (compound sealing).  IP68. Operating temperature ranges from -70 to 85 °С. Two-wire or four-wire connection is available.  4 tones of audible alarm.  In the course of order please specify text and background color.

 

TSZV-Exm-М-Prometheus 12-36 V

Body - galvanized steel. Power voltage 12-36 VDC.

119,00

TSZV-Exm-М-Prometheus 220 V

Body - galvanized steel. Power voltage 220 VAC.

119,00

TSZV-Exm-N-Prometheus 12-36 V

Body - stainless steel  12Х18Н10Т. Power voltage 12-36 VDC.

230,00

TSZV-Exm-N-Prometheus 220 V

Body - stainless steel  12Х18Н10Т. Power voltage 220 VAC.

230,00

Sound-and-light explosion-proof display
TSZV-Exi-Prometheus, intended for class 0, 1 and 2 explosion-hazard areas

Explosion-proof light display TSV-Exi-Prometheus. The device in designed for operation as light and sound alerter in security and fire alarm systems or as information display.  The device is used in class 0, 1 and 2 explosion-hazard areas, underground workings, mines and their ground-based structures. Two-wire or four-wire connection is available. 0ExiaIICT6 X / РОExiaI X explosion-proof marking (intrinsically safe circuit).  IP68. Operating temperature from -70 to 85 °С. In the course of order please specify text and background color. 

 

TSZV-Exi-N-Prometheus 12-36 V

Body - stainless steel  12Х18Н10Т. Power voltage 12-36 VDC.

226,00

Explosion-proof sound-and-light display. Intended for class 1 and 2 explosion-hazard areas

Explosion-proof sound-and-light display TSV-Exd-Prometheus. The device is used as sound-and-light alerter in security and fire alarm systems. The device is used in class 1 and 2 explosion-hazard areas. IP67. Operating temperature from - 70 to +85°C.  4 tones of audible alarm. 
In the course of order please specify type of cable gland (not included in the scope of supply), text and background color.

 

 TSZV-Exd-А-Prometheus 12-36 V

Body - aluminum alloy. Explosion-proof marking 1ExdIIBT6 X. Categories IIA, IIB. Power voltage 12-36 V AC/DC.

222,00

 TSZV-Exd-А-Prometheus 220 V

Body - aluminum alloy. Explosion-proof marking 1ExdIIBT6 X. Categories IIA, IIB. Power voltage 220 VAC.

238,00

 TSZV-Exd-N-Prometheus 12-36 V

Body -   stainless steel  12Х18Н10Т. Explosion-proof marking РВ ExdI X / 1ExdIIBT6 X. Category I. Power voltage 12-36 V AC/DC.

390,00

 TSZV-Exd-N-Prometheus 220 V

Body -   stainless steel  12Х18Н10Т. Explosion-proof marking РВ ExdI X / 1ExdIIBT6 X. Category I. Power voltage 220 VAC.

406,00

3. Explosion-proof alarms O-Exd-Prometheus

3.1 Explosion-proof light alarms OS-Exd-Prometheus

Explosion-proof light alarm OS-Exd-Prometheus;  Intended for class 1 and 2 
 explosion-hazard areas.

The device is intended for use as light alerter in security and fire alarm systems. The device is used in class 1 and 2 explosion-hazard areas.  IP68. t from -70 to +85°C. Emission color - white, three emission modes. Two-wire or four-wire connection is available.
In the course of order please specify type of cable gland (not included in the scope of supply).

 

 OS-Exd-А-Прометей 12-36 V

Body - aluminum alloy. Explosion-proof marking 1ExdIICT6 X. Power voltage 12-36 V AC/DC.

86,00

 OS-Exd-А-Прометей 220 V

Body - aluminum alloy. Explosion-proof marking 1ExdIICT6 X. Power voltage 220 VAC.

99,00

 OS-Exd-N-Prometheus 12-36 V

Body -   stainless steel  12Х18Н10Т. Explosion-proof marking РВ ExdI / 1ExdIICT6 X. Power voltage 12-36 V AC/DC.

164,00

 OS-Exd-N-Prometheus 220 V

Body -   stainless steel  12Х18Н10Т. Explosion-proof marking РВ ExdI / 1ExdIICT6 X. Power voltage 220 VAC.

181,00

3.2 Explosion-proof sound alarms OZ-Exd-Prometheus

Explosion-proof sound alarm OZ-Exd-Prometheus
; intended for class 1 and 2 explosion-hazard areas

The device is intended for operation as sound alerter in security and fire al systems. The device is used in class 1 and 2 explosion-hazard areas.  IP68. t from -70 to +85°C. 4 tones of audible alarm.  Two-wire or four-wire connection is available.
In the course of order please specify type of cable gland (not included in the scope of supply).

 

 OZ-Exd-А-Prometheus 12-36 V

Body - aluminum alloy. Explosion-proof marking 1ExdIICT6 X. Power voltage 12-36 V AC/DC.

86,00

 OZ-Exd-А-Prometheus 220 V

Body - aluminum alloy. Explosion-proof marking 1ExdIICT6 X. Power voltage 220 VAC.

103,00

 OZ-Exd-N-Prometheus 12-36 V

Body -   stainless steel  12Х18Н10Т. Explosion-proof marking РВ ExdI / 1ExdIICT6 X. Power voltage 12-36 V AC/DC.

164,00

 OZ-Exd-N-Prometheus 220 V

Body -   stainless steel  12Х18Н10Т. Explosion-proof marking РВ ExdI / 1ExdIICT6 X. Power voltage 220 VAC.

177,00

3.3 Explosion-proof sound-and-light alarms OSZ-Exd-Prometheus

Explosion-proof sound-and-light alarm OSZ-Exd-Prometheus; Intended for class 1 and 2
explosion-hazard areas

The device is intended for operation as light and sound alerter in security and fire alarm systems. The device is used in class 1 and 2 explosion-hazard areas.  IP68. t from -70 to +85°C. 4 tones of audible alarm.  Emission color - white, three emission modes. Two-wire or four-wire connection is available.
In the course of order please specify type of cable gland (not included in the scope of supply).

 

 OSZ-Exd-А-Prometheus 12-36 V

Body - aluminum alloy. Explosion-proof marking 1ExdIICT6 X. Power voltage 12-36 V AC/DC.

99,00

 OSZ-Exd-А-Prometheus 220 V

Body - aluminum alloy. Explosion-proof marking 1ExdIICT6 X. Power voltage 220 VAC.

115,00

 OSZ-Exd-N-Prometheus 12-36 V

Body -   stainless steel  12Х18Н10Т. Explosion-proof marking РВ ExdI / 1ExdIICT6 X. Power voltage 12-36 V AC/DC.

164,00

 OSZ-Exd-N-Prometheus 220 V

Body -   stainless steel  12Х18Н10Т. Explosion-proof marking РВ ExdI / 1ExdIICT6 X. Power voltage 220 VAC.

189,00

4. Explosion-proof horn loudspeaker GVR-Prometheus

4.1. Explosion-proof horn loudspeaker GVR-Exm-Prometheus

Explosion-proof horn loudspeaker GVR-Exm-Prometheus
for class 1 and 2
explosion-proof areas

Explosion-proof horn loudspeaker GVR-Exm-Prometheus is intended for voice broadcasting or any other audio information in fire-alarm, security systems at class 1 or 2 explosion-hazard areas. 1ExmbdIICT6 Gb X explosion-proof marking. t –65..+85°C. IP66. Power voltage 30 or 120 V. Frequency range 400-3500 Hz. Body - special plastic. It is recommended to use the device with junction box Relion-KKV-A.                            

 

 GVR-Exm-10-Prometheus

Nominal power 10 W. Sound pressure 100 dB.

127,00

 GVR-Exm-15-Prometheus

Nominal power 15 W. Sound pressure 102 dB.

136,00

 GVR-Exm-25-Prometheus

Nominal power 25 W.  Sound pressure 105 dB.

140,00

4.2. Explosion-proof horn loudspeaker GVR-Exd-Prometheus

Explosion-proof horn loudspeaker GVR-Exd-Prometheus
for class 1 and 2
explosion-proof areas

Explosion-proof horn loudspeaker GVR-Exd-Prometheus. The device is intended for broadcasting of voice messages and other audio information in fire-alarm, security systems at class 1 and 2 explosion-hazard areas. 1ExdIICT6 X explosion-proof marking.  t –65.. +85°C. IP66. Power voltage up to 100 V. Frequency range 400-4,500 Hz Body - aluminum alloy. In the course of order please specify type of cable gland (not included in the scope of supply).

 

 GVR-Exd-10-Prometheus

Nominal power 10 W.  Sound pressure 105 dB

144,00

 GVR-Exd-20-Prometheus

Nominal power 20 W.  Sound pressure 106 dB.

156,00

 GVR-Exd-30-Prometheus 

Nominal power 30 W.  Sound pressure 110 dB.

173,00

 GVR-Exd-50-Prometheus

Nominal power 50 W.  Sound pressure 112 dB.

222,00

5.  Explosion-proof voice horn-type loudspeakers RZOR-Prometheus

5.1. Explosion-proof voice horn-type loudspeaker RZOR-Exm-Prometheus 

Explosion-proof voice horn-type loudspeaker RZOR-Exm-Prometheus
for class 1 and 2
explosion-proof areas

Explosion-proof voice horn-type loudspeaker RZOR-Exm-Prometheus. The device is used to warn the public of fire and evacuation routes by playback of voice message recorded earlier. The device is used at class 1 and 2 explosion-hazard areas. 1ExmbdIICT6 Gb X explosion-proof marking. t –65..+85°C. IP66. Power voltage 12-36 DC. Frequency range 400-3,500 Hz. Body - special plastic. It is recommended to use the device with junction box Relion-KKV-A.   

 

 RZOR-Exm-10-Prometheus

Nominal power 10 W. Sound pressure 100 dB.

185,00

 RZOR-Exm-15-Prometheus

Nominal power 15 W. Sound pressure 102 dB.

210,00

 RZOR-Exm-25-Prometheus

Nominal power 25 W.  Sound pressure 105 dB.

214,00

5.2. Explosion-proof voice horn-type loudspeaker RZOR-Exd-Prometheus

Explosion-proof voice horn-type loudspeaker RZOR-Exd-Prometheus
for class 1 and 2
explosion-proof areas

Explosion-proof voice horn-type loudspeaker RZOR-Exd-Prometheus. The device is used to warn the public of fire and evacuation routes by playback of voice message recorded earlier. The device is used at class 1 and 2 explosion-hazard areas.  1ExdIICT6 X explosion-proof marking.  t –65.. +85°C. IP66. Power voltage 12-36 DC. Frequency range 400-4500 Hz Body - aluminum alloy. In the course of order please specify type of cable gland (not included in the scope of supply).

 

 RZOR-Exd-10-Prometheus

Nominal power 10 W.  Sound pressure 105 dB

230,00

 RZOR-Exd-20-Prometheus

Nominal power 20 W.  Sound pressure 106 dB.

251,00

 RZOR-Exd-30-Prometheus

Nominal power 30 W.  Sound pressure 110 dB.

263,00

 RZOR-Exd-50-Prometheus

Nominal power 50 W.  Sound pressure 112 dB.

337,00

 Name

 Description                   

Retail price, EUR (without VAT)

 SPECTRON HEAT CABINETS

1. Spectron-TSh general-purpose industrial heat cabinets

HEAT CABINETS For severe climate conditions of the Far North.

For severe climate conditions of the Far North. Temperature range from - 75°C to +60°C. Insulated heat cabinets with electrical heating. Automatic mode of maintaining the required temperature. Designed for installation of switching and electronic equipment.  IP66. Heating consumption power within 400 W. Power voltage 220 V AC. Number of cable glands - as required.

Spectron-TSH-300

Dimensions: 300 х 400 х 150 mm. Heating power 75 W.

148,00  

Spectron-TSH-500

Dimensions: 500 х 400 х 210 mm. Heating power 150 W.

238,00  

Spectron-TSH-600

Dimensions: 600 х 600 х 210 mm. Heating power 200 W.

283,00  

 

 Name

Description

Retail price, EUR (without VAT)

ACCESSORIES

1. Intrinsically safe barriers

Intrinsically safe barriers 

Intrinsically safe barrier is intended to provide explosion-proofness of electric circuits located at explosion-hazard areas. Intrinsically safe terminal complies with [Exia]IIC explosion-proof marking.

 

Intrinsically safe barrier Spectron-IB-01

Intrinsically safe active-type barrier for power-supply circuits of fire detectors, current consumption 0,25 mA, max. Output voltage 12V. Peak current 500 mA. Rinner - 5,1 Ohm 

46,00

Intrinsically safe barrier Spectron-IB-02

Intrinsically safe active-type barrier for loops of Fire alarm control and indicating equipment. Powered from alarm circuit. Current consumption 0.25 mA. Output voltage 24 V. Peak current 100 mA. Rinner - 6.8 Ohm

46,00

2. Voltage converters 220/12/24/36 V, explosion-proof version 

Spectron-UP-220-Exd voltage converters for class 1 and 2 explosion-hazard areas. 

Spectron-UP-220-Exd explosion-proof voltage converters are designed for converting incoming 220V voltage into output 12V, 24V and 36V voltage. IP68. t from - 60 to 90°C.   

 

Spectron-UP-220/12-А

Body - aluminum alloy. Uoutput - 12V. Ioutput 0.75 A. Explosion-proof marking 1ЕхdIICT5/Т6. Overall dimensions 140х140х77

82,00

Spectron-UP-220/24-A

Body - aluminum alloy. Uoutput - 24V. Ioutput 0.5 A. Explosion-proof marking 1ЕхdIICT5/Т6. Overall dimensions 140х140х77

82,00

Spectron-UP-220/36-А

Body - aluminum alloy. Uoutput - 36V. Ioutput 0.35 A. Explosion-proof marking 1ЕхdIICT5/Т6. Overall dimensions 140х140х77 

82,00

Spectron-UP-220/12-N

Body- stainless steel. Uoutput-12V. Ioutput 0.75 A. Explosion-proof marking РВ ЕхdI/1ЕхdIICT5/Т6 Overall dimensions 130х130х72.5

140,00

Spectron-UP-220/24-N

Body - stainless steel. Uoutput-24V. Ioutput 0.5 A. Explosion-proof marking РВ ЕхdI / 1ЕхdIICT5/Т6 Overall dimensions 130х130х72.5 

140,00

Spectron-UP-220/36-N

Body - stainless steel. Uoutput-36V. Ioutput 0.35 А. Explosion-proof marking РВ ЕхdI/ 1ЕхdIICT5/Т6 Overall dimensions 130х130х72.5

140,00

3. Test detectors

Test detector Spectron-IT-08

for checking IR-detectors Spectron-200 series

58,00

Test detector Spectron-IT-09

for checking UV-detectors Spectron-400 series 

91,00

Test detector Spectron-IT-10

to check multiband detectors of Spectron-600 series (spectral responsivity, nm IR 800-1100/UV 185-260)

91,00

Test detector Spectron-IT-11

to check multiband detectors of Spectron-600 series (spectral responsivity, nm IR 4300/ UV 185-260) 

123,00

Test explosion-proof detector Spectron-IT-12-Exd  (black)

Explosion-proof detector  for remote operability check of the detectors of "600-Exd"series with 2017 production date or later.  Operation range - 25m; Battery life - 50 hrs; 

460,00

Test explosion-proof detector Spectron-IT-12-Exd (red)

Explosion-proof detector  for remote    adjustment  of basic parameters of "600-Exd" series detectors with 2017 production date or later.   Operation range - 25m; battery life - 50 hrs; 

689,00

4. Explosion-proof junction boxes

Relion-KKV-A-P passage

Relion-KKV-A explosion-proof box is designed for connecting and splitting of electrical circuits of general and special purpose with 0.08...2.5mm cross-section cables in class 1 and 2 explosion-hazard areas. 1ExdIICT5/Т6 explosion-proof marking. IP67. Overall dimensions 140х140х77 mm. Body - aluminum alloy. 

33,00

Relion-KKV-A-U angular

33,00

Relion-KKV-A-T branch box

35,00

Relion-KKV-A-K cross 

37,00

Relion-KKV-N-P passage

Relion-KKV-N explosion-proof box is designed for connecting and splitting of electrical circuits of general and special purpose with 0.08...2.5mm cross-section cables in class 1 and 2 explosion-hazard areas. Explosion-proof marking РВ ЕхdI / 1ExdIICT5/Т6. Body - stainless steel 12Х18Н10Т.  IP67. Overall dimensions 130х130х72,5

99,00

Relion-KKV-N-U angular

99,00

Relion-KKV-N-T branch box

103,00

Relion-KKV-N-K four-way

111,00

Spectron-KKV-Exi-P passage

Spectron-KKV-Exi explosion-proof box is designed for connecting and splitting electrical circuits with 0.08...2.5mm cross-section cables in all types of explosion-hazard areas, IP65. 0ExiaIICT6 Х explosion-proof marking (intrinsically safe circuit), WAGO mounting clips, U up to 28V, I up to 0.12 A. Body material - polyamide.  Overall dimensions 175x127x55 

9,00

Spectron-KKV-Exi-U angular

9,00

Spectron-KKV-Exi-T branch box

10,00

Spectron-KKV-Exi-K cross

11,00

Spectron-MK-04-Exi-P passage

Spectron MK-04-Exi explosion-proof box is designed for two-wire or four-wire connection of detectors manufactured by NPO Spectron LLC.  0ExiaIICT6 explosion-proof marking   Х (intrinsically safe circuit) is used in all types pf explosion-hazard areas. Body material - polyamide. Overall dimensions 175x127x55 

17,00

Spectron-MK-04-Exi-U angular

17,00

Spectron-MK-04-Exi-T branch box

18,00

Spectron-MK-04-Exi-K cross

21,00

5. Joint boxes for connection of Spectron detectors 

Spectron-МК-03

For connection of Spectron-201, Spectron-403 fire detectors; two-wire loop.  IP54. Overall dimensions  110х110х50.

7,00

Spectron-MK-04

For connection of fire detectors of Spectron-200, Spectron-400, Spectron-600 series by two-wire or four-wire loop.  IP54.  Overall dimensions of junction box 110х110х50.

9,00

6. Cable gland

M-galvanized steel

Cable gland body material - galvanized steel

 

Cable gland-12-М

cable gland for installation with armored cable with outside diameter up to 12mm or metal hose with nominal inside diameter of 10mm.

7,00

Cable gland-15-М

cable gland for installation with cable in metal hose with nominal inside diameter of 15mm.

8,00

Cable gland-18-М

cable gland for installation with cable in metal hose with nominal inside diameter of 18mm.

9,00

Cable gland-20-М

cable gland for installation with cable in metal hose with nominal inside diameter of 20mm.

9,00

Fitting-G ½-М

nozzle for piping connection with G ½" thread.

5,00

Fitting-G ¾-М

nozzle for piping connection with G ¾" thread.

5,00

Cap-M

end cap М 20*1.5. 

4,00

N - Stainless steel

Cable gland body material - stainless steel  12Х18Н10Т 

 

Cable gland-12-N

cable gland for installation with armored cable with outside diameter up to 12mm or metal hose with nominal inside diameter of 10mm.

12,00

Cable gland-15-N

cable gland for installation with cable in metal hose with nominal inside diameter of 15mm.

15,00

Cable gland-18-N

cable gland for installation with cable in metal hose with nominal inside diameter of 18mm.

17,00

Cable gland-20-N

cable gland for installation with cable in metal hose with nominal inside diameter of 20mm.

18,00

Fitting-G ½-N

nozzle for piping connection with G ½" thread.

9,00

Fitting-G ¾-N

nozzle for piping connection with G ¾" thread.

9,00

Cap-N

end cap М20*1.5.

7,00

7. Sunscreens

SZK-02

for: fire detectors IPP Spectron-401-Exd-M/N; IPP Spectron-601-Exd-M/N.

18,00

SZK-14

for: UDP and IPR series 535 and 512

7,00

8. Mounting devices

Spectron-К-05-М

For equipment in aluminum-alloy body. Designed for reliable mounting of 101-Spectron-R/T-R thermal fire detectors on walls, pillars or ceiling.  

6,00

Spectron-К-05-N

For equipment in stainless-steel bodies. Designed for reliable mounting of 101-Spectron-T-R-N thermal fire detectors on walls, pillars or ceiling.

12,00

Spectron-К-06-М

For equipment in bodies of zinc-coated steel. Designed for reliable mounting of Spectron-401Exd and Spectron-601Exd flame fire detectors to posts or pillars 100-300mmin diameter.

35,00

Spectron-К-06-N

For equipment in stainless-steel bodies. Designed for reliable mounting of Spectron-401Exd and Spectron-601Exd flame fire detectors to posts or pillars 100-300mmin diameter.

58,00

9. Protective deices

Optic sunshade
Spectron-01-M

Optic sunshade is designed for reduction of viewing angle of Spectron-601-Exd, Spectron-607-Exd and Spectron-401-Exd flame fire detectors (all configurations).

58,00

Protection grill

To be used for protection of Spectron flame detectors in a plastic body in places with potential or mechanical damages (sport halls).

5,00

Optical filters

Recommended for controlled desensitization of Spectron-200 series IR detectors in facilities with increased background illumination. 

1,00

10. Lightning protection devices

Spectron GZ-P-12V

Supply circuits lightning protection device; nominal voltage 12V; clamping voltage 15V; Temperature range from -50...+85°C. 

18,00

Spectron GZ-P-24V

Supply circuits lightning protection device nominal voltage 24V; clamping voltage 33V; Temperature range from -50...+85°C.

18,00

Spectron GZ-P-220V

Supply circuits lightning protection device; nominal voltage 220V; clamping voltage 250V; Temperature range from -50...+85°C.

12,00

Spectron GZ-SP-12V

Lighting protection device for supply circuits and alarm circuits of analog equipment; nominal alarm circuit voltage 6V; nominal supply circuit voltage 12V; maximum supply circuit operating current 1.5A; Temperature range from -50...+85°C.

15,00

Spectron GZ-SP-24V

Lighting protection device for supply circuits and alarm circuits of analog equipment; nominal alarm circuit voltage 6V; nominal supply circuit voltage 24V; maximum supply circuit operating current 1.5A; Temperature range from -50...+85°C.

15,00

Spectron GZ-LAN

Lighting protection devices for Ethernet10/100 Base-TX local area network ports; protected pairs 1-2, 3-6; nominal voltage 5V; Temperature range from -50...+85°C.

25,00

Groza-100

SpectronGroza lightning protection device of 100 series is designed for protecting active end-used devices of security and fire alarm system (fire alarm control and indicating equipment, terminal detector) from overvoltage occurring in the alarm circuit as a result of electromagnetic impulse crosstalk occurring mainly during a lighting discharge.

 

101/1.24/33

No body, terminal block type DG128 Degson, 1 channel, nominal voltage 33V

6,00

104/2.24/33

IP54 body, terminal block type DG128 Degson, 2 channels, nominal voltage 33V

11,00

107/1.24/33

IP54 body, terminal block type DG128 Degson, 1 channel, nominal voltage 33V

7,00

110/8.24/33

No body, terminal block type DG128 Degson, 8 channels, nominal voltage 33V

46,00

Groza-200

SpectronGroza lightning protection device of 200 series is designed for protecting current consumers of security and fire alarm system included in alarm circuit disruption from overvoltage occurring in the alarm circuit as a result of electromagnetic impulse crosstalk occurring mainly during a lightning discharge. 

 

201/1.24/33

No body, terminal block type DG128 Degson, nominal voltage 33V

11,00

207/1.24/33

IP54, terminal block type DG128 Degson, nominal voltage 33V

17,00

Groza-300

SpectronGroza lightning protection device of 300 series is designed for protecting input and output circuits of devices in the security and fire alarm system with up to 2.5A current from overvoltage occurring in the alarm circuits as a result of electromagnetic impulse crosstalk occurring mainly during a lighting discharge.

 

301/1.24/33

No body, terminal block type DG128 Degson, power line nominal voltage 24V

9,00

307/1.24/33

IP54 body, terminal block type DG128 Degson, power line nominal voltage 24V

9,00