Thermal cable interface modules - MIT
Thermal cable interface modules - MIT
- Spectron-MIT-1;
- Spectron-MIT-2;
- Spectron-MIT-1-Exi;
- Spectron-MIT-2-Exi;
- Spectron-MIT-BI.
Thermal cable interface modules - MIT. Spectron-MIT-1,2, Spectron-MIT-1,2-Exi performs the functions of a processing unit for linear thermal fire detectors of maximum action and is designed to monitor the state of the sensitive element of the linear thermal fire detector IP104 "Spectron-thermal cable" of the STSW series (as well as its analogs) along its entire length and output of discrete and digital signals about its state to external circuits. |
Interface module for monitoring the condition of the thermal cable and transmitting information to the MIT-BI central unit. Depending on the current state, it generates discrete signals: standby mode, malfunction mode, fire mode. The supported length of the thermal cable loop is up to 3000 m, the operating temperature range is -40 ... +55° С. It is intended for work in single-wire lines. |
Interface module for monitoring the condition of the thermal cable and transmitting information to the MIT-BI central unit. Depending on the current state, it generates discrete signals: standby mode, malfunction mode, fire mode. The supported length of the thermal cable loop is up to 3000 m, the operating temperature range is -40 ... +55° С. It is intended for work in two-wire lines. |
Interface module for monitoring the status and receiving information from Spectron-MIT-1,2, Spectron-MIT-1,2-Exi. Depending on the current state, it generates discrete signals: standby mode, malfunction mode, fire mode. |
Interface module for monitoring the condition of the thermal cable and transmitting information to the MIT-BI central unit in explosion-proof areas. Depending on the current state, it generates discrete signals: standby mode, malfunction mode, fire mode. The supported length of the thermal cable loop is up to 3000 m, the operating temperature range is -40 ... +55° С. It is intended for work in single-wire lines. |
Interface module for monitoring the condition of the thermal cable and transmitting information to the MIT-BI central unit in explosion-proof areas. Depending on the current state, it generates discrete signals: standby mode, malfunction mode, fire mode. The supported length of the thermal cable loop is up to 3000 m, the operating temperature range is -40 ... +55° С. It is intended for work in two-wire lines. |
Modules MIT-1-Exi, MIT-2-Exi belong to the associated electrical equipment (according to GOST 31610.0-2014) and have output intrinsically safe electrical circuits of level "ia" of subgroup IIC, have an explosion protection marking for explosive gas and dust environments "[Ex ia Ga ] IIC", "[Ex ia Da] IIIC" and "[Ex ia Ma] I", comply with the requirements of GOST 31610.0-2014, GOST 31610.11-2014 and are intended for installation outside explosive areas of premises and outdoor installations, as well as outside hazardous areas mines and mines dangerous for firedamp. |