UV/IR4 Flame Detector Spectron-901-Exd for Hazardous Industrial Facilities and Critical Infrastructure Facilities
NEW EX-PROOF UV/IR4 FIRE ALARM FLAME DETECTOR HIGHLY IMMUNE TO ARC WELDING AND OTHER STRONG OPTICAL NOISES
- Spectron-901-Exd-А-HART
- Spectron-901-Exd-М-HART
- Spectron-901-Exd-N-HART
EX-PROOF UV/IR4 FIRE ALARM FLAME DETECTOR WITH VIDEO MODULE
- Spectron-901-Exd-А-В-HART
- Spectron-901-Exd-А-В-IP-HART
- Spectron-901-Exd-N-HART-В-HART
- Spectron-901-Exd-N-HART-В-IP-HART
Spectron-901-Exd series detectors detect manual arc and argon welding as false alarms |
||||||
For use in fire alarm and fire extinguishing systems in hazardous area zones 1 and 2 of enclosed buildings and open installations, as well as in underground mines, mining plants and their above-ground facilities. |
||||||
|
||||||
Flame detector in stainless steel housing is recommended for use in facilities exposed to acidic, alkaline and other chemically aggressive environments, sea water and salt fog. |
||||||
Output interfaces:
or
|
||||||
The Spectron-901 flame detector can be supplied with a video module:
The video module is designed to record alarm events. The video module is manufactured in a separate housing, mounted on one common bracket and located on the same axis as the flame detector. Power is supplied to the video module from the detector via an armored cable. A separate power supply board is installed in the detector for the operation of the video module. |
||||||
Photos from the analog video module are sent to the RS-485 interface located on the detector's circuit board and are transmitted to the receiving device via the Modbus RTU protocol at a rate of 1 photo per second. At the same time data is recorded and stored on the internal SD card. The video stream from the IP video module is transmitted to the operator (to a dedicated server, video recorder, etc.) via the Ethernet protocol and is simultaneously stored on the internal SD card. |
||||||
Flame detector in stainless steel housing is recommended for use in facilities exposed to acidic, alkaline and other chemically aggressive environments, sea water and salt fog. |
||||||
Circuit board of the device is equipped with a 3-stage lightning and surge protector, which allows using it without additional equipment for overvoltage protection. |
||||||
For configuring detector’s parameters, “Spectron” configurator program is used. The program allows:
Detectors with HART protocol are configured using HART-USB "Spectron" interface converter. To download the software from our website click this link. Detectors with Modbus/RTU digital protocol are configured using SB-RS-48 interface converter. To download the software from our website click this link. |
||||||
For facilities with harsh operating conditions, the detector sensitivity can be changed. Detection range modes:
|
||||||
The detector heater ensures full operation of the device at an ambient temperature of -70 to +90ºС. With the heating function disabled the operating temperature range is -55 to +90ºС. The detector remains operational with a short-term increase in temperature up to +135ºС. |
||||||
The field of view of Spectron-901-Exd series is 90º in the vertical, horizontal and all inclined planes. |
||||||
The flame detection range (in accordance with GOST R 53325-2012) 60 meters to TP5, 50 meters to TP6 |
||||||
Minimal response time, seconds |
0.1, 5, 15*, 25
(changeable by user, * - factory setting)
|
|||||
The transition of the detector from the Alarm mode to the Normal mode is carried out by disconnecting the power supply for at least 8 seconds |
||||||
Spectron-901-Exd Flame Detector |
A-HART |
М-HART |
N-HART |
|||
Wiring |
|
|
|
|||
Self-testing |
|
|
|
|||
Ingress Protection |
|
|
|
|||
Type of explosion protection |
|
|
|
|||
The warranty period of is 18 months from the date of commissioning, but not more than 24 months from the date of manufacturing. |
||||||
Flame detectors work with explosion-proof test emitters:
The range of emitters is 25 meters. |
or by e-mail: support@spectron-ops.ru